Description
The Dromex DR-A1P2-EN A1P2 Twin Filter is a reusable combination gas-and-particulate cartridge set designed for Dromex twin-cartridge respirators. It helps protect the wearer against organic gases and vapours (boiling point above 65°C with good warning properties) plus medium-level particulate filtration, making it a practical choice for tasks like spray painting, pesticide handling, and welding-related exposure.
VERIFIED KEY FEATURES
- A1P2 combination protection: organic gases/vapours + particulates
- Twin-cartridge design for use as a pair on compatible twin-cartridge respirators
- Ergonomic, lightweight, low-profile shape to help maintain field of vision
- Activated carbon layer to remove harmful gases/vapours and help neutralise unpleasant odours
- Large surface area for improved loading capacity and longer use potential (conditions dependent)
- Easy screw-on attachment with right-hand (clockwise) thread
- No metal fittings in the device
- Black cartridge body with A1P2 colour coding (brown/white) on marking/label
- Not for use on single-port masks
BENEFITS (WORKPLACE-READY)
When your team is exposed to solvent-type fumes and airborne particulates, reliable respiratory filtration is non-negotiable. This A1P2 twin filter set is built for day-to-day industrial work where comfort, visibility, and fast changeovers matter. The low-profile twin design integrates well with other PPE and helps reduce visual obstruction, while the reusable cartridge format supports planned filter change routines. With clear standards approvals and a straightforward screw-on fitment, it’s a dependable replacement set for keeping your Dromex twin-cartridge respirator ready for the next shift.
SPECIFICATIONS AND TECHNICAL DETAILS (CONFIRMED DATA ONLY)
Brand: Dromex
Model/Item Code: DR-A1P2-EN
Product Type: Twin reusable combination gas and particulate filter cartridges (set of 2)
Filter Type/Class Marking: A1P2 R D
Protection Provided:
- Organic gases and vapours with boiling points greater than 65°C and good warning properties (A1)
- Particulates (P2; medium level of particulate protection)
Compatibility: - Compatible with Dromex twin cartridge respirators DH302 (EN302 Twin Mask) and DHFFM
- Do not use these twin cartridges with Dromex single-port masks
Breathing Resistance: - At 15 l/min: maximum 1.7 mbar
- At 47.5 l/min: maximum 6.4 mbar
- After clogging test at 47.5 l/min: maximum 9 mbar
Breakthrough Time (BTT): - Cyclohexane (C6H12): > 70 minutes at 10 ml/m³
Filter Penetration Maximum: - Sodium chloride at 95 l/min: 6%
- Paraffin oil at 95 l/min: 0.6%
Maximum Gas Capacity: 1000 ppm
Filter Efficiency: 95%
Materials (as listed): - Retainer: Polypropylene
- Pre-filter pad: Spunbond scrim + P2 meltblown layer
- Cartridge lid and body: ABS (Acrylonitrile Butadiene Styrene)
- Carbon layer: A1 carbon
- Additional media layers: Polyester sheets
Compliance & Conformity: - CE marked under PPE Regulation (EU) 2016/425
- Certified as Category III PPE
- Standards: EN 143:2021 and EN 14387:2004 + A1:2008
- NRCS homologated to SANS 54387:2007; NRCS Type Approval No. NRCS/8072/0420
- BSI The Netherlands: Module B certificate CE 784120; Module D certificate CE 784124; CE No. 2797
Packaging: Packed as one set (2) of cartridges, shrink wrapped in a polybag
Shelf Life: 4 years for gas filters if stored correctly (expiry date printed on the cartridge)
Storage Conditions: Store at +2°C to 55°C with relative humidity below 75%, away from direct sunlight and contamination
Cleaning: Wipe exterior with a damp cloth only; do not use solvents; do not allow water to enter the filter (cleaning does not extend filter life)
HOW TO USE (SIMPLE)
- Check the packaging is intact and confirm the cartridges are within the printed expiry date.
- Ensure you have the correct respirator: Dromex DH302 (EN302 Twin Mask) or Dromex DHFFM.
- Screw each cartridge onto the mask filter connectors clockwise (right-hand thread) until secure. Do not over-tighten.
- Perform your normal fit checks on the respirator before entering the work area.
- Replace the cartridges if breathing resistance increases, if you detect chemical breakthrough (smell/taste/irritation), or if the cartridges become damaged.
- After use, store the cartridges/mask in a clean, dry container or suitable mask storage bag away from contamination.
CUSTOMER REVIEWS
- Thando M.
“Easy to fit onto our twin-cartridge masks and the low-profile shape doesn’t get in the way of my face shield. Works well for our paint prep area.” - Elaine P.
“We use these on the workshop respirators for fumes and dust. They feel comfortable on the mask setup and the changeover is quick.” - Johan V.
“Good quality cartridges and clearly marked. We keep spare sets on hand and swap them as soon as breathing becomes harder.”
FAQS
- Does this filter come in different sizes?
No. The cartridges are one size and are designed to fit specific compatible Dromex twin-cartridge respirators. - Which masks are these cartridges compatible with?
They are compatible with Dromex twin cartridge respirators DH302 (EN302 Twin Mask) and DHFFM. They must not be used on Dromex single-port masks. - What does A1P2 mean for protection?
A1 is for organic gases and vapours with boiling points above 65°C and good warning properties. P2 provides medium-level particulate filtration. - How do I know when to replace the cartridges?
Replace immediately if breathing becomes difficult, if you detect chemical breakthrough by smell/taste/irritation, or if the cartridge is damaged. - Can I wash or clean the cartridges to extend their life?
No. You may wipe the exterior with a damp cloth, but do not use solvents and do not allow water to enter the filter. Cleaning does not extend filter life. - Can I use these in any environment?
They are not for oxygen-deficient areas, oxygen-enriched atmospheres, explosive atmospheres, unknown contaminant conditions, or for firefighting. Always use within your workplace safety limits and established change-out schedule.
INDUSTRIES / WORKPLACE APPLICATIONS (UP TO 10)
- Painting and coating operations
- Welding and metal fabrication
- General manufacturing and industry
- Chemical handling and processing
- Oil and gas environments
- Agriculture (including pesticide-related tasks)
- Water treatment and utilities
- Pharmaceutical production areas
- Laboratories
- Automotive and aviation manufacturing
STAY READY FOR THE NEXT JOB
Keep your Dromex twin-cartridge respirator performing as intended with a correctly matched A1P2 replacement filter set. The DR-A1P2-EN is built for practical comfort, clear visibility, and straightforward change-outs—helping your team maintain consistent respiratory protection across demanding, contaminant-prone tasks.